• Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer
  • Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer

Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer

Line Voltage: 85.0~265.0V
Peak Line Voltage: 120V~375V
Line Frequency: 45.0~65.0Hz
Neutral-Ground Voltage: 0.0~10.0V
RCD and GFCI Trip Time: 1ms~6.5s
Voltage Drop Load Current: 12/15/20A
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
HT5908B
Power Supply
6*1.5V AAA Batteries
Product Weight
254G/0.56lb
Certificate
Ce/ETL/RoHS
Transport Package
Carton
Specification
194mm*78mm*37mm/7.64"*3.07"*1.46"
Trademark
HOTOTECH
Origin
China
HS Code
9030339000
Production Capacity
50000 Set a Mouth

Product Description

HT-5908B--Circuit Analyzer

feature

--data storage
--Quickly check the correct wiring
--Identifies proper wiring in 3-wire receptacles
--solve faulty splices and connections,
--solve incorrect wiring
--solve undersized wiring
--solve faulty GFCIs
--solve faulty or incorrectly wired AFCIs
--solve incorrect line voltage
--solve poor ground quality
--TRMS AC voltage measuremen
--ower quality monitor


the photo show 
Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer


specifications
Specifications Range Resolution Accuracy
Line voltage 85.0~135.0V 0.1V ±(1.0%+2)
Peak Line Voltage 120.0~190.0V 0.1V ±(1.0%+2)
Voltage with Loading equipments 10.0~135.0V 0.1V ±(2.5%+2)
Line frequency 45.0~65.0HZ 0.1HZ ±(1.0%+2)
Impedance-live and Neutral & Earth 0.00~3.00Ω 0.01Ω ±(2.5%+2)
  >3.00Ω 0.01Ω NO ensure
Neutral-Ground Voltage 0.0~10.0V 0.1V ±(2.5%+2)
RCD trip time 1ms~6.5S 1mS ±(1.0%+2)
RCD trip current 30mA~37mA 0.1mA ±(1.0%+2)
GFCI trip time 1ms~6.5S 1mS ±(1.0%+2)
GFCI trip current 6mA~9mA 0.1mA ±(1.0%+2)
Voltage drop 0.1~99.9% 0.1% ±(2.5%+2)
Voltage drop load current 12/15/20A    

General
Power supply:6*1.5V AAA Batteries
Product size:194mm*78mm*37mm/7.64"*3.07"*1.46"
Product weight:254g/0.56lb
Certificate:CE/ETL/RoHS
Safety rating:CAT III 300V
Accessories include:Power cord ,Carry bag,Battery and user´s manual


Company Profile
Introduction


visit customers
Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer

Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer
certificate
HT-5908B--Circuit Analyzer


feature

--data storage
--Quickly check the correct wiring
--Identifies proper wiring in 3-wire receptacles
--solve faulty splices and connections,
--solve incorrect wiring
--solve undersized wiring
--solve faulty GFCIs
--solve faulty or incorrectly wired AFCIs
--solve incorrect line voltage
--solve poor ground quality
--TRMS AC voltage measuremen
--ower quality monitor
the photo show 
Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer


specifications
Specifications Range Resolution Accuracy
Line voltage 85.0~135.0V 0.1V ±(1.0%+2)
Peak Line Voltage 120.0~190.0V 0.1V ±(1.0%+2)
Voltage with Loading equipments 10.0~135.0V 0.1V ±(2.5%+2)
Line frequency 45.0~65.0HZ 0.1HZ ±(1.0%+2)
Impedance-live and Neutral & Earth 0.00~3.00Ω 0.01Ω ±(2.5%+2)
  >3.00Ω 0.01Ω NO ensure
Neutral-Ground Voltage 0.0~10.0V 0.1V ±(2.5%+2)
RCD trip time 1ms~6.5S 1mS ±(1.0%+2)
RCD trip current 30mA~37mA 0.1mA ±(1.0%+2)
GFCI trip time 1ms~6.5S 1mS ±(1.0%+2)
GFCI trip current 6mA~9mA 0.1mA ±(1.0%+2)
Voltage drop 0.1~99.9% 0.1% ±(2.5%+2)
Voltage drop load current 12/15/20A    
General
Power supply:6*1.5V AAA Batteries
Product size:194mm*78mm*37mm/7.64"*3.07"*1.46"
Product weight:254g/0.56lb
Certificate:CE/ETL/RoHS
Safety rating:CAT III 300V
Accessories include:Power cord ,Carry bag,Battery and user´s manual

Company Profile
Introduction

visit customers
Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer

Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer
certificate
Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer

product package
Short Circuit & Earth Fault Indicator Trms Voltage GFCI RCD Circuit Breaker Analyzer





FQA
-Do we support OEM or ODM?    
-Will the original R&D manufacturing plant have a price advantage?
-Are our products high quality products?
-Do we have a good team? 
-Does our product support global after-sales service?
-Are our products certified?

every answer is "YES
"!
product package



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
27
Year of Establishment
2009-05-26