After-sales Service: | Lifetime Maintenance |
---|---|
Power Supply: | AC220V /AC380V |
Certification: | CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | HT-CD-1116 |
Related Standard Test Requirements | Gb4208-2008, etc |
Structural system | The laboratory is composed of test table, storage tank, control box, turntable, and spray system |
Spray system | It is composed of water pump, water pressure gauge and fixed nozzle bracket |
Total size of the laboratory | Depth 3000 w 2500 height 2500 mm (in actual size) |
Ip12 dripping device | Diameter 0.4mm |
Ip34 rain unit | Ip3:120°,ip4:180° |
Ip56 rain test device | 06.3mm;o12.5mm |
Dip test tank ipx 7 | See technical protocol for details |
General turntable system | 2, customizable in size |
Navar | Adopt touch screen and plc and step closed-loop control system |
Water pump flow control: | Use the frequency converter for speed regulation |
Spray water flow | Through the flow meter closed-loop feedback system, the touch screen can be directly set |
Flowmeter | Electronic flowmeter |
Control function | Up and down height of drip tray, angle of pendulum tube, sprinkler flow, rotary speed, test time setting, automatic drainage well of dripping tray |
Protector | Vulnerability protection, water shortage protection, overload protection, safe distance protection |
Source | Ac 380v 50hz 5kw |