After-sales Service: | 24 Hours Online |
---|---|
Warranty: | 1 Year |
Max Diameter of Workpiece: | 2000mm |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
product name | Ball prick tester at the bottom of the battery pack |
product model | HT-CD-1126 |
control method | Remote computer control + remote video monitoring + static distance wireless remote control alignment |
Test space size | W3000mm * D2000mm * H No height limit |
The load of tooling platform | 2000kg |
The duplex-site test structure | Double-station test structure + automatic fire extinguishing pool |
(1) Needled battery rack: test space size W3000mm * D2000mm * H no height limit | |
(2) Ball hit battery table: test space size W3000mm * D2000mm * H no height limit; with automatic fire extinguishing pool | |
(3) The needle ball strike shares a set of test host | |
(1) Bottom ball strike needle test host structure: vertical servo motor screw transmission structure, moving from bottom to top; | |
test structure | (2) Battery pack ball strike fixing frame structure: the left-hand side fixed battery pack installation ball strike frame; |
(3) Battery pack needle prick mobile frame structure: the right side; battery pack can move left and right, up and down; automatically move the battery pack to the immersed water for fire extinguishing; | |
(3) Fire extinguishing pool; with fire extinguishing pool, SUS304 of stainless steel, | |
Install the battery pack in a fixed way | (1) Installation and fixing method of battery pack and ball strike fixing frame: simulate the on-board fixing method of battery pack, which can be adjusted in three-axis position |
(3) Installation and fixing method of the battery pack and acupuncture mobile frame: the pressing plate is fixed to the assembly platform | |
Working table height | The battery pack installation work table is about 1900mm away from the base height; |
Close held remote control remote point | It can closely control the ball head or steel needle on the bottom of the battery pack, which is convenient for operation. The remote control is equipped with emergency stop and power switch, safe, reliable, convenient and fast |
Power range | The 1-100 kN force can be freely adjusted |
Force value accuracy | 0.2%FS (steady-state) |
Test speed | Speed of bottom ball hit: 0.01 mm/s-10 mm/s (adjustable speed) |
Bottom needle speed: 0.01mm / S-25 mm/s (speed adjustable) | |
Ball shot needle speed accuracy | ±0.1mm/s |
Displacement accuracy of ball pin | ±0.1mm |
Test trip (Z-axis) | The 0-450mm is customizable |
Position control of the test | Control X-axis Y-axis to find the test position; along with explosion-proof camera, remote video monitoring, clearly see the ball hitting point and dynamic test status. |
Fire fighting method | The acupuncture battery pack automatically moves above the pool and sink to extinguish the fire |
Two cameras | 1: The test host is equipped with 1 camera to follow the Z and Y axis of the ball head |
2: The laboratory installed a camera to monitor the test status of the whole laboratory | |
Ball hit the head | diameter? The 150mm solid hemisphere, high temperature resistance, high strength, can withstand the sphere impact force of 100 kN sphere. |
Software for built-in data acquisition | Built-in voltage, temperature acquisition (customizable) |
synchronous data acquisition system | Simultaneous acquisition and ball hitting / needling; force, displacement, speed, timing, total voltage, auxiliary temperature, and can be automatically saved into a data file |
Synchronize output graphics | Data were dynamically collected at high speed synchronization and curves were dynamically drawn |
source | AC380V50Hz |
aggregate capacity | 10 kW |
outline dimension | Size of host: W7500 * D4500 * H3200mm (subject to design) |
Computer control cabinet W850 * D700 * H1200mm (subject to design) | |
weight of equipment | Host machine: about 15,000 kg |
Computer control cabinet: 50kg | |
Equipment installation conditions | 1. Installation and place: the equipment can be unloaded through a 5-ton extended arm forklift. After moving into the laboratory, adjust the distance between the back of the equipment and the left and right sides 1000mm from the wall. The operating space of the front is 3500mm, which is convenient for the upper and lower battery pack test and fixing the equipment. Power cord ground wire (forklift or crane to install battery pack) |
2. Ground load-bearing: 1,500 kg/m. The ground should be level flat. | |
3. Laboratory: the whole laboratory should have a ventilation system, which can discharge the smoke leaked during the test; good lighting and easy to watch the operation equipment. | |
4. The passage of the laboratory should facilitate the transportation of batteries and related transportation vehicles. People can be evacuated in case of special emergency. | |
5. The laboratory should be equipped with corresponding fire fighting facilities to facilitate the use of fire fighting tools. Such as fire water, fire extinguisher...class | |
6. The laboratory needs to be equipped with aerial cranes to facilitate the loading and unloading of the battery pack. |