Photovoltaic module rupture tester/Module breakage test
Standard:
According to IEC61730-2004 standard requirement
Purpose:
This test is provide confidence that cutting or piercing injuries can be minimized if the module is broken
Technical specifications:
1,Impact height:300mm~1220mm
2,Device test frame
2.1,The inner dimension of test sample: according to customer's pv module size requirement
2.2,Sample frame material :channel width >=100mm, thickness 3mm
2.3,Installation the protection device at the both of side
3,Impactor
3.1,The mass of impactor:45.5 ± 0.5kg
3.2,Inner filling diameter 2.5-3.0mm's pellets
Impact height |
300mm~1220mm |
channel width |
>=100mm |
thickness |
3mm |
The mass of impactor |
45.5 ± 0.5kg |
Inner filling diameter |
2.5-3.0mm's pellets |
Impactor
1. The exterior of the bag according to the standard use the wrapped with tape
2. The inner filling diameter 2.5-3.0mm ( the material is pellets or steel ball )
3.The mass of impactor :45.5 ± 0.5kg
4. The ratio of widest diameter to height is between 1:1,5 to 1:1,4
Distance between the module surface and the bag:≤13mm
Distance between the module center and the bag:≤50mm
Safety Function
1. With the safety protection frame
2. Anti-secondary impact function
Testing parameter
1. Impact height: 300mm , 450mm, 600mm, 750mm, 900mm, 1200mm
2.Impact height display accurate: 0.1mm
3. Impactor rise ways: Automatic rise/ Jog rise
4. Release ways: arriving predetermined height, the cylinder automatic release
5. Real-time display rise height
6.The Remote control distance:≤10m
7.Touch screen control and display
We treasure the value of good quality , reasonable price and efficient service with customer satisfaction . we expert ourselves in providing our customers the best suitable testing designs and high quality testing machines to make you the utmost profit
Please feel free to contact us for any enquiries from our wide range of products