After-sales Service: | 24 Hours Online |
---|---|
Warranty: | 1 Year |
Trademark: | HOTOTECH |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Applicable Test Standard :
IEC61215-2:2016 MQT03,IEC61215-2:2021MQT03,IEC61730-2:2016 MST16
The Mainly Specifications :
1.Input Characteristics:Voltage:220VAC,±10%,single phase,Frequency:47-63Hz,Fuse:8A/250VAC
2.DC Withstand Voltage Test:Rated Output:15KV DC
3.Leakage Current High Limit Setting:Range:0.0-5.000mA,Resolution:0.01uA,Accuracy:±(2%setting value+2dgts)
4.Leakage Current Low Limit Setting:Range:0.00-5.000mA,Resolution:0.01uA,Accuracy:±(2% setting value+2dgts)
5.Voltage Setting:Range:0-15KV DC,Resolution:1V,Accuracy:±(2% setting value +5V)
6.Voltage Stability:±(1% setting value +5V)
7.Ramp Time:Range:0.4-999.9S,Resolution:0.1S,Accuracy:±(0.1% setting value +0.05 S)
8.Test Time:Range:0.5-999.9S,Resolution:0.1S,Accuracy:±(0.1% setting value +0.05 S)
9.ARC-fault Detection:1-9 level can be set,0 arc-fault condition will not be detected
10.Voltage Display:Range:0-15KV DC, Resolution:0.01KV,Accuracy:±(3% display value +0.005V)
11.Current Display:Range:0.0001-5.000mA DC,Resolution:0.01mA (0.1uA),Accuracy:±(3% display value +3dgts)
12.Insulation Resistance Test:Rated output:3500V DC
13.Voltage Setting:Range:500 - 3500V DC, Resolution:1V,Accuracy:±(3% setting value +5V)
14.Voltage Display Range:0.500KV -3.500KV DC,Resolution:0.001KV,Accuracy:±(3% display value +5V)
15.Resistance Value:Range:100kΩ-99GΩ,Accuracy:±(3% display value +3dgts) (100kΩ-9.99GΩ)±(20% display value +3dgts) (10GΩ-99GΩ)
16.Resistance High Limit Setting:100kΩ-99GΩ
17.Resistance Low Limit Setting:100kΩ-99GΩ
18.Delay Time Judgment:Range:0.1 - 999.9 S,Resolution:0.1s,Accuracy:±(0.1% display value +0.05S)
19.Ground Resistance Tester
19.1Output Current Setting:Range:10.0~100.0A,Accuracy:±(2% display value +5dgts)
19.2Ground Resistance Upper Limit Setting:
0 ~ 600.0 mΩ(10.00A ~ 20.00A)
0 ~ 300.0 mΩ(20.01A ~ 30.00A)
0 ~ 200.0 mΩ(30.01A ~ 40.00A)
0 ~ 150.0 mΩ(40.01A ~ 50.00A)
0 ~ 120.0 mΩ(50.01A ~ 60.00A)
0 ~ 100.0 mΩ(60.01A ~ 70.00A)
0 ~80.0 mΩ(70.01A ~ 80.00A)
0 ~60.0 mΩ(80.01A ~ 90.00A)
0 ~50.0 mΩ(90.01A ~ 100.00A)
Accuracy:±(2% setting value +3dgts)
19.3Ground Resistance Lower Limit Setting:
0 ~ 600.0 mΩ(10.00 ~ 20.00A)
0 ~ 300.0 mΩ(20.01A ~ 30.00A)
0 ~ 200.0 mΩ(30.01A ~ 40.00A)
0 ~ 150.0 mΩ(40.01A ~ 50.00A)
0 ~ 120.0 mΩ(50.01A ~ 60.00A)
0 ~ 100.0 mΩ(60.01A ~ 70.00A)
0 ~80.0 mΩ(70.01A ~ 80.00A)
0 ~60.0 mΩ(80.01A ~ 90.00A)
0 ~50.0 mΩ(90.01A ~ 100.00A)
Accuracy:±(2% setting value +3dgts)
20.Testing Time:0.5 ~ 999.9 S ,(0 continuous testing)
21.Time Accuracy:±(0.1% setting value +0.05S)
Company profile:
Note: The final price is based on customized standards