4.01 product name |
Battery thermal runaway test machine |
4.02 product model number |
HT-CD-1107 |
4.03 control mode |
Remote computer control + video surveillance |
4.04 trigger mode |
Overcharge and heating two modes (standard) |
4.05 dc charge trigger control parameters |
Control object |
Single-unit cell overcharge control |
Control method |
Computer programming control |
Overcharge flow voltage can be controlled |
Controller |
Programmable intelligent dc power supply |
Number of channels of the overcharge mode |
1 channel |
Overcharge voltage range |
0~10v |
Overvoltage-free accuracy |
≤0.3%+2lsb |
Overcharge voltage resolution |
0.001v |
Over the charging flow range |
0~300a |
Overcharging flow accuracy |
≤0.3%+2lsb |
Resolution of the overcharge flow |
0.1a |
4.06 ac heating trigger control parameters |
Control object |
Heating element: Heating plate (maximum power: 3kw) |
The size and power can be customized according to the demand |
Control method |
Computer programming control |
1: Controlled rate control: 4-7ºC / min; the temperature rise rate is adjustable |
2: The power of each heating board can be multistep or power progressive control such as 50w / min~500w / min power progressive; the power can be set arbitrarily |
3. Synchronously generated curve to reflect the real and intuitive embodiment of the test state |
Controller |
Programmable intelligent ac variable frequency conversion power supply |
Number of channels |
1 channel ac220v-3kw |
Output |
Phase number: 1 φ 2w; |
Phase voltage: Low-grade 0-150vac / high-grade 0-300vac; |
Frequency: 45-200hz,0.1step; |
Maximum current: L=200v-25a/h=400v-12.5a |
Led show |
Voltage vrms, |
Current arms, |
Frequency fre, |
Power wattage, |
Power factor pf |
Power supply steady pressure rate |
0.1 |
Load steady pressure rate |
1% |
Accuracy of measurement |
Voltage voltage: 0.5%fs + 5 dgt |
Current current: 0.5%fs + 5 dgt |
Power wattage: 0.5%fs + 5 dgt |
Frequency frequency: 0.01%fs + 5 dgt |
Set accuracy |
Voltage: Voltage: 1%fs |
Frequency frequency: 0.1%fs |
Limited flow setting |
O-max current (exceeding current setting power protection, stop output) |
Protect |
Overcurrent over current overtemperature over temp |
Short-circuit short circuit overload over load |
Communication interface |
Rs232c |
4.07 data acquisition system |
Voltage acquisition channel: 2 channels |
Voltage acquisition range: 0-10v |
Voltage acquisition accuracy: 0.2% fsr |
Voltage acquisition frequency: 50 hz |
Temperature acquisition channel: 4 channels |
Temperature acquisition range: 0~800ºC |
Temperature acquisition accuracy: ± 1ºC |
Temperature acquisition frequency: 50 hz |
4.08 monitoring system |
Camera resolution: 1080p, 5 million pixels; |
4.09 explosion-proof box (optional) |
(1) volume: 1m3/1.5m3/2m3.. |
(2) steel plate thickness: 5mm / 8mm / 10mm; single layer or double layer, can be customized |
4.11 equipment size |
Power control host: W750 * d750 * h1200 mm; |
Size of explosion-proof box is customized |
4.12 equipment weight |
Power control host: 50kg |
Explosion-proof box: 0.5t~2t |
4.13 equipment power supply |
Ac220v /ac380v |
4.14 total power |
4kw |