After-sales Service: | 24 Hours Online |
---|---|
Power Supply: | AC380V6kw |
Certification: | CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.01 Product name | Simulated high-altitude test box |
1.02 Product model number | HT-CD-1124-12m3 |
1.03 Test space | W2000*D3000*H2000mm |
1.04 Material of the inner box | Q235B steel plate, thickness of 10mm + Q235B profile reinforcement and welding |
1.05 Battery pack placement | The battery pack is placed directly on the bottom of the inner box, bearing 2000kg |
1.06 Material of the outer box | Spray treatment of cold-rolled steel plate |
1.07 Pressure range | 8.0 kPa ~ normal pressure (adjustable) |
1.08 Pressure adjustment accuracy | 0.1KPa |
1.09 Vacuum time | From the atmospheric pressure to the 11.3kPa for 30min |
1.10 Pressure rise time | Less than 10min |
1.11 System seal | No more than 1 kPa for leakage within 30min |
1.12 High-voltage terminal post | Two groups, a total of 4, resistant to 400A, 1000V DC with a number identification to prevent errors |
1.13 Low-voltage terminal post | Two groups, 4,20A, 60V DC 400A, 1000V DC; with number identification to prevent errors |
1.14 Data line interface | Group 2,8 core line |
1.15 Observation window | 1.2 superposition of thickened tempered explosion-proof glass; prevent one cracked glass from being sucked into the box and causing safety accident; add a layer of explosion-proof glass to avoid this accident |
2. Window size: W400 * H400MM | |
1.16 Boxes of doors | (1) Size: about W2300XH2300mm |
(2) Manual opening and closing: the door is equipped with heavy load hinge and plane thrust bearing, reduce friction, open and close the door more easily | |
(3) equipped with 2 sets of door locks: door lock in the form of pressing lock, manual switch more effort | |
1.17 video camera | Install a video surveillance camera from outside the window |
1.18 Lighting lamp | 1 high and low temperature explosion-proof lamp source LED lamp; power 50W |
1.19 Overall dimensions | W2400*D3300*H2800mm |
1.20 Total weight of the equipment | About 6 tons |
1.21 Power supply | AC380V6kW |
1.22 Gas source | ≥0.6MPa |
1.23 Smoke exhaust pipe | OD φ 60mm |
1.24 Installation conditions | 1. Ground load-bearing capacity of 1,500 kg/m² |
2. Laboratory space W6500 * D5000 * H4500mm | |
3. Lighting system is installed in the laboratory with an illumination level of 200 lumens | |
4. The laboratory is equipped with compressed gas sources | |
5. The laboratory is equipped with smoke discharge pipe |