After-sales Service: | Lifetime Maintenance |
---|---|
Power Supply: | 380V ± 10%, 220V ± 10%, 50 / 60Hz |
Certification: | CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameter | Impact platform body | Maximum test load (kg) |
25 (including fixture) can be customized | Equipment usage conditions | Ambient condition | Temperature (ºC):0~40 | |
Worktop size (mm) | The number of 3,00,350 is customizable | ||||||
Impact direction | Perpendicular | Humidity: 85% | |||||
Impulse shape | Half sinusoidal | Rear peak serrated (optional) | Supply voltage | Three-phase 380v ± 10%, 220v ± 10%, 50 / 60hz | |||
Peak acceleration (m/s2) | 50~15000 | 150~1000 | |||||
Pulse duration (ms) | 60~0.8 | 18~6 | System consumption | Total power was <5kw | |||
Outline dimension (mm) | 1100×750×2300 | Foundation requirements | Standard machinery industrial plant floor | ||||
Total equipment weight (kg) | 1600 | ||||||
Improve the way | Hydraulic drive, steel wire rope lifting | Reliability | The average fault-free cumulative working time is 1000h; the storage time of rubber products in a clean and normal temperature environment is not less than 3 years; | ||||
Channel selection | Four channels (standard equipment) are scalable | ||||||
Impact controller | Input select | Charge / voltage | |||||
Charge range | ±104pc | ||||||
Control accuracy | <3% | Applied code | Gjb150 gjb360 gjb548 gb/t2423 gjb1217 jjg541iec68-2-27 |