After-sales Service: | Lifetime Maintenance |
---|---|
Power Supply: | AC220V /AC380V |
Certification: | CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | HT-CD-1112-252L | HT-CD-1112--288C |
Single-layer inner box size | W600xd700xh600 mm | W800 xd600 xh600 mm |
Carton size | W1280xd1780xh1960 mm | W1450*h1960*d1720 mm |
Structure mode | The test box is designed as an integral type of two studio structures | |
Temperature range | -40ºC--+150ºC | |
Temperature fluctuation | ±0.3ºC | |
Heating rate | Average 3.0ºC / min (non-linear no-load) | |
Cooling rate | Average 1.0ºC / min (non-linear no load) | |
Temperature uniformity | ± 2ºC (empty, constant) | |
Watch the window | W300xh400 mm, three layers of vacuum-tempered glass | |
Calibrating terminal | Install 12 sets of wiring posts on the left side of the box and connect with the test cabinet | |
Cooling-down method | Air cooling / water cooling is optional | |
Compression engine | German blog compressor | |
Control method | Touch screen can control plc, with usb interface, with rj 485 interface can be connected to computer control, special network control software, convenient remote monitoring, data collection | |
Internal box material | Sus304 # mirror stainless steel, 1.0mm thick, shotcrete fluoride dragon insulation | |
External box material | Galvanized plate, powder spraying, high temperature plasticizing, 1.2mm thick | |
Supply voltage | AC380V 50HZ 12KW | AC380V 50HZ 14KW |
Safe guarding | Automatic explosion-proof pressure relief device, explosion-proof chain, three-color lamp alarm device, remote control, smoke exhaust device, fire extinguishing device, etc | |
Expand the function | Develop communication protocol and charge and discharge machine matching use |